Product Description

AC Gear Motor
4 RK 25 R C C F G10
Outer Diameter Motor Type Power Capacity Speed Motor Votalge Output Shaft Shape Accessories Derived Code
2 – 60mm
3 – 70mm
4 – 80mm
5 – 90mm
6 – 100mm
IK – Induction
RK – Reversible
TK – Torque
6 – 6W
15 – 15W
40 – 40W
60 – 60W
90 – 90W
120 – 120W
140 – 140W
180 – 180W
200 – 200W
250 – 250W
R   A -1 Phase 110V
C – 1 Phase 220V
C2 – 1 Phase 110V/220V
S – 3 Phase 220V
S2 – 3 Phase 220V/380V
S3 – 3 Phase 380V
S4 – 3 Phase 440V
SS3 – 3 Phase 220V/380V
A – Round Shaft
C – Toothed Shaft 
T/P – Thermally Protected
F – Fan
M – Electro-manetic
Z – Damping
Dimension
Shaft Length

AC Gearhead
4 GN 60 K G12 T
Outer Diameter Motor Shaft Shape Gear Ratio Bearing Model Output Shaft Diameter Installation Method
2 – 60mm
3 – 70mm
4 – 80mm
5 – 90mm
6 – 104mm
GN – Bevel Gear Shaft
GU – Bevel Gear Shaft
GS – Strengthen T-shaped installation
GZ – Right-angle gearbox
GM – Intermediate gearbox
60 – 1:60 K – Standard Rolling Bearings
RT – Right Angle
RC – Right Angle Hollow
G12 –  Ф12mm L – Screw Hole
T – Through Hole

Specifications of Motor
Motor Type Motor Model No. Description Rating Start Condenser Gear Model No.
Cylindncal
Output Shaft
Pinion Cut
Output Shaft
Force Peripheral Wave No. Valtage Current Start Turning Moment Turning Moment Revolving No. Capacity Resistance Voltage Pairing Bearing Middle Gear
( W ) ( Hz ) ( V ) ( A ) ( gcm ) ( gcm ) ( rpm ) ( uF ) ( V )
Rerersible
 Motor
4RK25A-A 4RK25GN-A 25 50 110 0.60 1950 1950 1250 8 250 4GN-K 4GN10X
60 110 0.55 1650 1620 1500 7
4RK25A-C 4RK25GN-C 50 220 0.30 1950 1950 1250 2 500 4GN-K 4GN10X
60 220 0.27 1650 1620 1500 1.8
4RK30A-A 4RK30GN-A 30 50 110 0.70 2400 2350 1250 10 250 4GN-K 4GN10X
60 110 0.65 1950 1950 1500 8
4RK30A-C 4RK30GN-C 50 220 0.35 2400 2350 1250 2.5 500 4GN-K 4GN10X
60 220 0.32 1950 1950 1500 2
4RK40A-A 4RK40GN-A 40 50 110 0.80 3250 3250 1250 16 250 4GN-K 4GN10X
60 110 0.75 3600 2600 1500 14
4RK40A-C 4RK40GN-C 50 220 0.40 3250 3250 1250 4 500 4GN-K 4GN10X
60 220 0.38 2600 2600 1500 3.5
Induction
 Motor
4IK25A-A 4IK25GN-A 25 50 110 0.55 1650 1950 1250 7 250 4GN-K 4GN10X
60 110 0.50 1380 1620 1500 6
4IK25A-C 4IK25GN-C 50 220 0.28 1650 1950 1250 1.8 500 4GN-K 4GN10X
60 220 0.25 1350 1620 1500 1.5
4IK30A-A 4IK30GN-A 30 50 110 0.65 2050 2350 1250 10 250 4GN-K 4GN10X
60 110 0.60 1750 1950 1500 8
4IK30A-C 4IK30GN-C 50 220 0.33 2050 2350 1250 2.2 500 4GN-K 4GN10X
60 220 0.30 1750 1950 1500 2
External Dimension
Type Reduction Ratio L1(mm) L2(mm) L3(mm)
4IK(RK)25A(GN) 1:3 ~ 1:20 86 32 118
4IK(RK)30A(GN) 86 32 118
4IK(RK)40A(GN) 101 32 133
4IK(RK)25A(GN) 1:25 ~ 1:180 86 44 130
4IK(RK)30A(GN) 86 44 130
4IK(RK)40A(GN) 101 44 145
Gear Head-Torque Table (kg.cm) 
 ( kg.cm x 9.8 ÷ 100 ) = N.m
 r/min 500 300 200 150 120 100 75 60 50 30 20 15 10 7.5 6 5 3
Gear Redcution Ratio 50Hz 3 5 7.5 10 12.5 15 20 25 30 50 75 100 150 200 250 300 500
60Hz 3.6 6 9   15 18   30 36 60 90 120 180   300 360 600
Permissible Load 25W kg.cm 4 6.7 10 13.3 16 20 26.7 32 39 65 80 80 80 80 80 80 80
30W kg.cm 4.8 8 12 16 20 24 32 38 45 76 80 80 80 80 80 80 80
40W kg.cm 6.7 11 16 21.3 28 33 42 54 65 80 80 80 80 80 80 80 80
Note: Speed figures are based on synchronous speed, the actual output speed, under rated torque conditions, is about 10~20% less than synchronous speed.
Grey background indicates: output shaft of geared motor rotates in the same direction as output shaft of motor
White background indicates: rotation in the opposite direction

FAQ
Q: How about your company?
A: We are a gear motor factory established in 1995 and located in HangZhou city of china. 
     We have more than 1200 workers. Our main product is AC micro gear motor 6W to 250W, 
     AC small gear motor 100W to 3700W, brush DC motor 10W to 400W, brushless motor10W to 750W,
     drum motor 60W to 3700W, planetary gearbox,and worm gearbox,etc.

Q: How about your quality control?
A: From raw material to finished products, we have strict and complete IPQC. 
     And the advanced test-ing machine can assure of qualified products delivered.

Q: How to choose a suitable motor?
A: If you have gear motor pictures or drawings to show us, 
    or you tell us detailed specs like volt-age, speed, torque, motor size, the working model of the motor, needed lifetime and noise level, etc. 
    please do not hesitate to let us know, then we can suggest a suitable motor per your request.

Q: Can you make the gear motor with customizing specifications?
A: Yes, we can customize per your request for the voltage, speed, torque, and shaft size and shape. 
     if you need additional wires or cables soldered on the terminal or need to add connectors, or capacitors, or EMC we can make it too.

Q: What’s your lead time?
A: Usually our regular standard product will need 10-15days, a bit longer for customized products. 
     But we are very flexible on the lead time, it will depend on the specific orders.

Q: What is your MOQ?
A: If delivered by sea, the minimum order is 100 pieces, if deliver by express, there is no limit.

Q: Do you have the item in stock?
A: l am sorry we do not have the item in stock, All products are made with orders.

Q: How to contact us?
A: You can send us an inquiry.
  /* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Speed: Constant Speed
Number of Stator: Single-Phase
Function: Driving, Control
Casing Protection: Protection Type
Number of Poles: 4
Customization:
Available

|

induction motor

Can you explain the concept of motor efficiency and how it relates to AC motors?

Motor efficiency is a measure of how effectively an electric motor converts electrical power into mechanical power. It represents the ratio of the motor’s useful output power (mechanical power) to the input power (electrical power) it consumes. Higher efficiency indicates that the motor converts a larger percentage of the electrical energy into useful mechanical work, while minimizing energy losses in the form of heat and other inefficiencies.

In the case of AC motors, efficiency is particularly important due to their wide usage in various applications, ranging from residential appliances to industrial machinery. AC motors can be both induction motors, which are the most common type, and synchronous motors, which operate at a constant speed synchronized with the frequency of the power supply.

The efficiency of an AC motor is influenced by several factors:

  1. Motor Design: The design of the motor, including its core materials, winding configuration, and rotor construction, affects its efficiency. Motors that are designed with low-resistance windings, high-quality magnetic materials, and optimized rotor designs tend to have higher efficiency.
  2. Motor Size: The physical size of the motor can also impact its efficiency. Larger motors generally have higher efficiency because they can dissipate heat more effectively, reducing losses. However, it’s important to select a motor size that matches the application requirements to avoid operating the motor at low efficiency due to underloading.
  3. Operating Conditions: The operating conditions, such as load demand, speed, and temperature, can influence motor efficiency. Motors are typically designed for maximum efficiency at or near their rated load. Operating the motor beyond its rated load or at very light loads can reduce efficiency. Additionally, high ambient temperatures can cause increased losses and reduced efficiency.
  4. Magnetic Losses: AC motors experience losses due to magnetic effects, such as hysteresis and eddy current losses in the core materials. These losses result in heat generation and reduce overall efficiency. Motor designs that minimize magnetic losses through the use of high-quality magnetic materials and optimized core designs can improve efficiency.
  5. Mechanical Friction and Windage Losses: Friction and windage losses in the motor’s bearings, shaft, and rotating parts also contribute to energy losses and reduced efficiency. Proper lubrication, bearing selection, and reducing unnecessary mechanical resistance can help minimize these losses.

Efficiency is an important consideration when selecting an AC motor, as it directly impacts energy consumption and operating costs. Motors with higher efficiency consume less electrical power, resulting in reduced energy bills and a smaller environmental footprint. Additionally, higher efficiency often translates to less heat generation, which can enhance the motor’s reliability and lifespan.

Regulatory bodies and standards organizations, such as the International Electrotechnical Commission (IEC) and the National Electrical Manufacturers Association (NEMA), provide efficiency classes and standards for AC motors, such as IE efficiency classes and NEMA premium efficiency standards. These standards help consumers compare the efficiency levels of different motors and make informed choices to optimize energy efficiency.

In summary, motor efficiency is a measure of how effectively an AC motor converts electrical power into mechanical power. By selecting motors with higher efficiency, users can reduce energy consumption, operating costs, and environmental impact while ensuring reliable and sustainable motor performance.

induction motor

What are the safety considerations when working with or around AC motors?

Working with or around AC motors requires careful attention to safety to prevent accidents, injuries, and electrical hazards. Here are some important safety considerations to keep in mind:

  • Electrical Hazards: AC motors operate on high voltage electrical systems, which pose a significant electrical hazard. It is essential to follow proper lockout/tagout procedures when working on motors to ensure that they are de-energized and cannot accidentally start up. Only qualified personnel should perform electrical work on motors, and they should use appropriate personal protective equipment (PPE), such as insulated gloves, safety glasses, and arc flash protection, to protect themselves from electrical shocks and arc flash incidents.
  • Mechanical Hazards: AC motors often drive mechanical equipment, such as pumps, fans, or conveyors, which can present mechanical hazards. When working on or near motors, it is crucial to be aware of rotating parts, belts, pulleys, or couplings that can cause entanglement or crushing injuries. Guards and safety barriers should be in place to prevent accidental contact with moving parts, and proper machine guarding principles should be followed. Lockout/tagout procedures should also be applied to the associated mechanical equipment to ensure it is safely de-energized during maintenance or repair.
  • Fire and Thermal Hazards: AC motors can generate heat during operation, and in some cases, excessive heat can pose a fire hazard. It is important to ensure that motors are adequately ventilated to dissipate heat and prevent overheating. Motor enclosures and cooling systems should be inspected regularly to ensure proper functioning. Additionally, combustible materials should be kept away from motors to reduce the risk of fire. If a motor shows signs of overheating or emits a burning smell, it should be immediately shut down and inspected by a qualified professional.
  • Proper Installation and Grounding: AC motors should be installed and grounded correctly to ensure electrical safety. Motors should be installed according to manufacturer guidelines, including proper alignment, mounting, and connection of electrical cables. Adequate grounding is essential to prevent electrical shocks and ensure the safe dissipation of fault currents. Grounding conductors, such as grounding rods or grounding straps, should be properly installed and regularly inspected to maintain their integrity.
  • Safe Handling and Lifting: AC motors can be heavy and require proper handling and lifting techniques to prevent musculoskeletal injuries. When moving or lifting motors, equipment such as cranes, hoists, or forklifts should be used, and personnel should be trained in safe lifting practices. It is important to avoid overexertion and use proper lifting tools, such as slings or lifting straps, to distribute the weight evenly and prevent strain or injury.
  • Training and Awareness: Proper training and awareness are critical for working safely with or around AC motors. Workers should receive training on electrical safety, lockout/tagout procedures, personal protective equipment usage, and safe work practices. They should be familiar with the specific hazards associated with AC motors and understand the appropriate safety precautions to take. Regular safety meetings and reminders can help reinforce safe practices and keep safety at the forefront of everyone’s minds.

It is important to note that the safety considerations mentioned above are general guidelines. Specific safety requirements may vary depending on the motor size, voltage, and the specific workplace regulations and standards in place. It is crucial to consult relevant safety codes, regulations, and industry best practices to ensure compliance and maintain a safe working environment when working with or around AC motors.

induction motor

Can you explain the basic working principle of an AC motor?

An AC motor operates based on the principles of electromagnetic induction. It converts electrical energy into mechanical energy through the interaction of magnetic fields. The basic working principle of an AC motor involves the following steps:

  1. The AC motor consists of two main components: the stator and the rotor. The stator is the stationary part of the motor and contains the stator windings. The rotor is the rotating part of the motor and is connected to a shaft.
  2. When an alternating current (AC) is supplied to the stator windings, it creates a changing magnetic field.
  3. The changing magnetic field induces a voltage in the rotor windings, which are either short-circuited conductive bars or coils.
  4. The induced voltage in the rotor windings creates a magnetic field in the rotor.
  5. The magnetic field of the rotor interacts with the rotating magnetic field of the stator, resulting in a torque force.
  6. The torque force causes the rotor to rotate, transferring mechanical energy to the connected shaft.
  7. The rotation of the rotor continues as long as the AC power supply is provided to the stator windings.

This basic working principle is applicable to various types of AC motors, including induction motors and synchronous motors. However, the specific construction and design of the motor may vary depending on the type and intended application.

China supplier New CHINAMFG Industrial Geared Gear Box Electric AC Right Angle Grae Motor   wholesaler China supplier New CHINAMFG Industrial Geared Gear Box Electric AC Right Angle Grae Motor   wholesaler
editor by CX 2024-03-29