Product Description
Models Numbers
Product Description
GSK ZJY series spindle servo motor
Adopt the totally enclosed air cooling structure without the shell, good shape and compact structure. |
Employ the optimized electromagnetic design with the characters of the low noise, smooth running and high efficiency. |
Introduce the imported bearing in high precision, and the rotor reaches the high precision with the dynamic balance process, which can ensure the motor running stable and reliable with small vibration and low noise in the maximum rotational speed range. |
Adopt the enameled wire of corona resistance, the motor can be driven reliably at the ambient temperature of -15″C~40″C and in the environment with the dust and oil mist. |
Employ the encoder at high speed and in high precision, and it can be incorporated into the drive with high performance for controlling the speed and the position in high precision. |
The overload capacity is strong and the motor is reliably running at Reliable operation at 150% of rated power for 30 minutes. |
The speed regulation range is wide and the maximum speed can reach 12000r/min. |
Impact resistance, long lifetime and high cost performance. |
Protection level: IP54 (GB/T 4942.1-2006) |
Insulation grade: Grade F (GB 755-2008) |
Vibration grade: Grade B (GB 10068-2008) |
Models Numbers
SR.NO | Meaning |
(1) | The spindle servo motor |
(2) | Flange size ( 182, 208, 265, 320 ) |
(3) | Design sequence number (None: Original A, B,C… : design sequence number) |
(4) | Rated power (Unit:KW) |
(5) | Rated speed (V: 600 r/min, W: 750 r/min, A: 1000 r/min, B:1500 r/min, C: 2000 r/min, E: 3000 r/min ) |
(6) | Max. speed (G: 15000 r/min,F: 12000 r/min, H:10000 r/min, M:7000 r/min, L:4500 r/min ) |
(7) | D:Dual-Speed type |
(8) | Structure installation type: (B5 flange installation, B3 footing installation, B35 flange & footing installation ) |
(9) | Encoder type (None: Incremental 1571 p/r, A2: Incremental 5000 p/r, A5: Absolute 21 bit ) |
(10) | Look the terminal box position in view from the shaft end (None: on the top, R: on the right, L: on the left). |
(11) | Shaft end (None: strainht shaft , Y1: with the standard key slot) |
(12) | Customer special order numbers are bracketed in two capitals. |
(13) | Power supply voltage (none: three-phase 380~440V, L: three-phase 220V) |
Product Parameters
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-1)
Model | ZJY182A-3.7BL | ZJY182A-5.5BL | ZJY182A-1.5BH | ZJY182A-2.2BH | ZJY182A-3.7BH | ZJY182A-5.5BH | ZJY182A-3.7EG | ZJY182A-5.5EG | ZJY182A-7.5EG | |
Item | ||||||||||
Rated power(kW) | 3.7 | 5.5 | 1.5 | 2.2 | 3.7 | 5.5 | 3.7 | 5.5 | 7.5 | |
Adaptive driver | GS/GR3050 | GS/GR3050 | GS/GR3048 | GS/GR3048 | GS/GR3050 | GS/GR3075 | GS/GR3050 | GS/GR3075 | GS/GR3100 | |
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | |||||||||
Rated current(A) | 10.4 | 13.8 | 7.3 | 7.5 | 15.5 | 17.3 | 11.6 | 16.6 | 20.2 | |
Rated | 53.7 | 53.5 | 53.9 | 53.6 | 53.1 | 53.5 | 103.2 | 103.3 | 103.2 | |
frequency(Hz) | ||||||||||
Rated torque(N·m) | 24 | 35 | 9.5 | 14 | 24 | 35 | 11.8 | 17.5 | 24 | |
30min power(kW) | 5.5 | 7.5 | 2.2 | 3.7 | 5.5 | 7.5 | 5.5 | 7.5 | 11 | |
30min current(A) | 14.8 | 18 | 9.3 | 11 | 19.6 | 21.8 | 15.4 | 20.7 | 26.6 | |
30min torque(N·m) | 35 | 48 | 14 | 24 | 35 | 48 | 17.5 | 24 | 35 | |
Rated speed(r/min) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 3000 | 3000 | 3000 | |
Constant power range(r/min) | 1500~4500 | 1500~4500 | 1500~8000 | 1500~8000 | 1500~8000 | 1500~8000 | 3000~12000 | 3000~12000 | 3000-12000 | |
Max. speed(r/min) | 4500 | 4500 | 10000 | 10000 | 10000 | 10000 | 15000 | 15000 | 15000 | |
Moment of inertia(kg·m2) | 0.0068 | 0.5712 | 0.004 | 0.0054 | 0.0083 | 0.5712 | 0.0054 | 0.0068 | 0.0083 | |
Weight(kg) | 37 | 52 | 27 | 32 | 43 | 52 | 32 | 37 | 43 | |
Installation type | IM B5 or B35 | |||||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 37W 0.1A | |||||||||
Overall dimension (refer to figures) |
A | 182 | 182 | 182 | 182 | 182 | 182 | 182 | 182 | 182 |
B | 91 | 91 | 91 | 91 | 91 | 91 | 91 | 91 | 91 | |
C | 123 | 123 | 123 | 123 | 123 | 123 | 123 | 123 | 123 | |
D | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | |
E | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | |
F | 371 | 436 | 319 | 346 | 401 | 436 | 346 | 371 | 401 | |
G | 249 | 314 | 197 | 224 | 279 | 314 | 224 | 249 | 279 | |
H | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | |
I | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
J | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | |
K | 158 | 158 | 158 | 158 | 158 | 158 | 158 | 158 | 158 | |
L | 93 | 93 | 93 | 93 | 93 | 93 | 93 | 93 | 93 | |
N | 156 | 156 | 156 | 156 | 156 | 156 | 156 | 156 | 156 | |
P | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | |
Q | 184 | 249 | 132 | 159 | 214 | 249 | 159 | 184 | 214 | |
S | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | |
T | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
Z | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-2)
Model | ZJY208A-3.7WL | ZJY208A-2.2AM | ZJY208A-3.7AM | ZJY208A-5.5AM | ZJY208A-5.5BL | ZJY208A-7.5BL | ZJY208A-9BL | ZJY208A-3.7BM | |
Item | |||||||||
Rated power(kW) | 3.7 | 2.2 | 3.7 | 5.5 | 5.5 | 7.5 | 9 | 3.7 | |
Adaptive driver | GS/GR3050 | GS/GR3048 | GS/GR3050 | GS/GR3075 | GS/GR3050 | GS/GR3075 | GS/GR3100 | GS/GR3050 | |
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | ||||||||
Rated current(A) | 11.3 | 6.7 | 10.2 | 16.3 | 12.9 | 17.9 | 21.6 | 8.6 | |
Rated | 27.3 | 35.7 | 35.7 | 35.7 | 53.3 | 52.9 | 52.6 | 52.9 | |
frequency(Hz) | |||||||||
Rated torque(N·m) | 47 | 21 | 35 | 53 | 35 | 48 | 57.3 | 24 | |
30min power(kW) | 5.5 | 3.7 | 5.5 | 7.5 | 7.5 | 11 | 12 | 5.5 | |
30min current(A) | 16 | 10.6 | 14.2 | 20.5 | 16.8 | 24 | 27.2 | 12.7 | |
30min torque(N·m) | 70 | 35 | 53 | 72 | 48 | 70 | 76.4 | 35 | |
Rated speed(r/min) | 750 | 1000 | 1000 | 1000 | 1500 | 1500 | 1500 | 1500 | |
Constant power range(r/min) | 750~3500 | 1000~4000 | 1000~4000 | 1000~4000 | 1500~4500 | 1500~4500 | 1500~4500 | 1500-5000 | |
Max. speed(r/min) | 4500 | 7000 | 7000 | 7000 | 4500 | 4500 | 4500 | 7000 | |
Moment of inertia(kg·m2) | 0.571 | 0.0142 | 0.0196 | 0.571 | 0.0143 | 0.0196 | 0.5716 | 0.0142 | |
Weight(kg) | 77 | 51 | 66 | 77 | 51.5 | 66 | 77.5 | 51 | |
Installation type | IM B5 or B35 | ||||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 40W 0.14A | ||||||||
Overall dimension (refer to figures) |
A | 208 | 208 | 208 | 208 | 208 | 208 | 208 | 208 |
B | 104 | 104 | 104 | 104 | 104 | 104 | 104 | 104 | |
C | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 | |
D | 215 | 215 | 215 | 215 | 215 | 215 | 215 | 215 | |
E | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
F | 524 | 414 | 469 | 524 | 414 | 469 | 524 | 414 | |
G | 395 | 285 | 340 | 395 | 285 | 340 | 395 | 285 | |
H | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | |
I | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | |
J | 38h6 | 28h6 | 38h6 | 38h6 | 38h6 | 38h6 | 48h6 | 28h6 | |
K | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | |
L | 106 | 106 | 106 | 106 | 106 | 106 | 106 | 106 | |
N | 180 | 180 | 180 | 180 | 180 | 180 | 180 | 180 | |
P | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Q | 320 | 210 | 265 | 320 | 210 | 265 | 320 | 210 | |
S | 80 | 60 | 80 | 80 | 80 | 80 | 110 | 60 | |
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Z | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-3)
Model | ZJY208A-5.5BM | ZJY208A-7.5BM | ZJY208A-2.2BH | ZJY208A-3.7BH | ZJY208A-5.5BH | ZJY208A-7.5BH | ZJY208A-11CM | ZJY208A-11CH | |
Item | |||||||||
Rated power(kW) | 5.5 | 7.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 11 | |
Adaptive driver | GS/GR3050 | GS/GR3075 | GS/GR3048 | GS/GR3050 | GS/GR3075 | GS/GR3100 | GS/GR3100 | GS/GR3100 | |
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | ||||||||
Rated current(A) | 13 | 17 | 8.9 | 12.6 | 18.4 | 22.4 | 28.3 | 28.3 | |
Rated | 52.4 | 52.7 | 52.6 | 52.5 | 52.4 | 52.6 | 69.1 | 69 | |
frequency(Hz) | |||||||||
Rated torque(N·m) | 35 | 48 | 14 | 24 | 35 | 48 | 52.6 | 52.5 | |
30min power(kW) | 7.5 | 11 | 3.7 | 5.5 | 7.5 | 11 | 15 | 15 | |
30min current(A) | 16.9 | 24.6 | 13.8 | 18 | 24 | 32.2 | 37 | 37 | |
30min torque(N·m) | 48 | 70 | 24 | 35 | 48 | 70 | 71.6 | 71.6 | |
Rated speed(r/min) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 2000 | 2000 | |
Constant power range(r/min) | 1500~5000 | 1500~5000 | 1500~5000 | 1500~5000 | 1500~8000 | 1500~8000 | 2000~7000 | 2000-8000 | |
Max. speed(r/min) | 7000 | 7000 | 10000 | 10000 | 10000 | 10000 | 7000 | 10000 | |
Moment of inertia(kg·m2) | 0.0196 | 0.571 | 0.0093 | 0.0142 | 0.0196 | 0.571 | 0.5716 | 0.571 | |
Weight(kg) | 66 | 77 | 49 | 51 | 66 | 77 | 77.5 | 77 | |
Installation type | IM B5 or B35 | ||||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 40W 0.14A | ||||||||
Overall dimension (refer to figures) |
A | 208 | 208 | 208 | 208 | 208 | 208 | 208 | 208 |
B | 104 | 104 | 104 | 104 | 104 | 104 | 104 | 104 | |
C | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 | |
D | 215 | 215 | 215 | 215 | 215 | 215 | 215 | 215 | |
E | 80 | 80 | 60 | 60 | 80 | 80 | 110 | 80 | |
F | 469 | 524 | 364 | 414 | 469 | 524 | 524 | 524 | |
G | 340 | 395 | 235 | 285 | 340 | 395 | 395 | 395 | |
H | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | |
I | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | |
J | 38h6 | 38h6 | 28h6 | 28h6 | 38h6 | 38h6 | 48h6 | 38h6 | |
K | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | |
L | 106 | 106 | 106 | 106 | 106 | 106 | 106 | 106 | |
N | 180 | 180 | 180 | 180 | 180 | 180 | 180 | 180 | |
P | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Q | 265 | 320 | 160 | 210 | 265 | 320 | 320 | 320 | |
S | 80 | 80 | 53 | 60 | 80 | 80 | 110 | 80 | |
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Z | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-4)
Model | ZJY208A-5.5CF | ZJY208A-7.5CF | ZJY208A-11EH | ZJY208A-5.5EF | ZJY208A-7.5EF | ZJY208A-11EF | ZJY265A-5.5WL | ZJY265A-7.5WL | ||
Item | ||||||||||
Rated power(kW) | 5.5 | 7.5 | 11 | 5.5 | 7.5 | 11 | 5.5 | 7.5 | ||
Adaptive driver | GS/GR3075 | GS/GR3100 | GS/GR3100 | GS/GR3050 | GS/GR3075 | GS/GR3100 | GS/GR3075 | GS/GR3100 | ||
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | |||||||||
Rated current(A) | 19 | 25.8 | 25.2 | 12.8 | 17.7 | 25.2 | 16.3 | 21.4 | ||
Rated | 69 | 69 | 102.2 | 102.9 | 102.2 | 102.2 | 26.6 | 26.7 | ||
frequency(Hz) | ||||||||||
Rated torque(N·m) | 26.3 | 35.8 | 35 | 17.5 | 24 | 35 | 70 | 95.5 | ||
30min power(kW) | 7.5 | 11 | 15 | 7.5 | 11 | 15 | 7.5 | 11 | ||
30min current(A) | 24 | 34.9 | 31.6 | 16 | 23.3 | 31.7 | 20.8 | 30.1 | ||
30min torque(N·m) | 35.8 | 52.5 | 48 | 24 | 35 | 48 | 95.5 | 140 | ||
Rated speed(r/min) | 2000 | 2000 | 3000 | 3000 | 3000 | 3000 | 750 | 750 | ||
Constant power range(r/min) | 2000~10000 | 2000~10000 | 3000~9000 | 3000~10000 | 3000~10000 | 3000~10000 | 750~3500 | 750-3500 | ||
Max. speed(r/min) | 12000 | 12000 | 10000 | 12000 | 12000 | 12000 | 4500 | 4500 | ||
Moment of inertia(kg·m2) | 0.0142 | 0.0196 | 0.0196 | 0.0093 | 0.0142 | 0.0196 | 0.0606 | 0. 0571 | ||
Weight(kg) | 51 | 66 | 66 | 49 | 51 | 66 | 107 | 125 | ||
Installation type | IM B5 or B35 | IM B5 or B3 | ||||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 40W 0.14A | Three-phase AC 380~440V 50/60Hz 70W 0.21A | ||||||||
Overall dimension (refer to figures) |
A | 208 | 208 | 208 | 208 | 208 | 208 | 265 | 265 | |
B | 104 | 104 | 104 | 104 | 104 | 104 | 132 | 132 | ||
C | 160 | 160 | 160 | 160 | 160 | 160 | 185 | 185 | ||
D | 215 | 215 | 215 | 215 | 215 | 215 | 265 | 265 | ||
E | 60 | 80 | 80 | 60 | 60 | 80 | 110 | 110 | ||
F | 414 | 469 | 469 | 364 | 414 | 469 | 487 | 533 | ||
G | 285 | 340 | 340 | 235 | 285 | 340 | 347 | 392 | ||
H | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 230h7 | 230h7 | ||
I | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | ||
J | 28h6 | 38h6 | 38h6 | 28h6 | 28h6 | 38h6 | 48h6 | 48h6 | ||
K | 212 | 212 | 212 | 212 | 212 | 212 | 256 | 256 | ||
L | 106 | 106 | 106 | 106 | 106 | 106 | 135 | 135 | ||
N | 180 | 180 | 180 | 180 | 180 | 180 | 230 | 230 | ||
P | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | ||
Q | 210 | 265 | 265 | 160 | 210 | 265 | 270 | 315 | ||
S | 60 | 80 | 80 | 60 | 60 | 80 | 110 | 110 | ||
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | ||
Z | 12 | 12 | 12 | 12 | 12 | 12 | 15 | 15 |
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-5)
Model | ZJY265A-11WL | ZJY265A-7.5AM | ZJY265A-11AM | ZJY265A-15AM | ZJY265A-7.5BM | ZJY265A-11BM | ZJY265A-15BM | ZJY265A-18.5BM | ZJY265A-22BM | |
Item | ||||||||||
Rated power(kW) | 11 | 7.5 | 11 | 15 | 7.5 | 11 | 15 | 18.5 | 22 | |
Adaptive driver | GS/GR3148 | GS/GR3100 | GS/GR3148 | GS/GR3150 | GS/GR3075 | GS/GR3100 | GS/GR3150 | GS/GR3150 | GS/GR3198 | |
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | |||||||||
Rated current(A) | 30 | 21.5 | 30.9 | 48.3 | 18 | 26 | 35 | 48.7 | 58 | |
Rated | 27.2 | 35.2 | 35.2 | 35.1 | 52.3 | 52.2 | 51.9 | 51.8 | 51.7 | |
frequency(Hz) | ||||||||||
Rated torque(N·m) | 140 | 72 | 105 | 143 | 48 | 70 | 95 | 118 | 140 | |
30min power(kW) | 15 | 11 | 15 | 18.5 | 11 | 15 | 18.5 | 22 | 30 | |
30min current(A) | 41 | 29 | 40.2 | 56 | 26 | 34 | 42 | 54.7 | 73 | |
30min torque(N·m) | 191 | 105 | 143 | 177 | 70 | 95 | 118 | 140 | 191 | |
Rated speed(r/min) | 750 | 1000 | 1000 | 1000 | 1500 | 1500 | 1500 | 1500 | 1500 | |
Constant power range(r/min) | 750~3500 | 1000~4000 | 1000~4000 | 1000~4000 | 1500~5000 | 1500~5000 | 1500~5000 | 1500~5000 | 1500-5000 | |
Max. speed(r/min) | 4500 | 7000 | 7000 | 7000 | 7000 | 7000 | 7000 | 7000 | 7000 | |
Moment of inertia(kg·m2) | 0. 0571 | 0. 0571 | 0.571 | 0.0869 | 0. 0571 | 0.571 | 0.571 | 0.571 | 0.1043 | |
Weight(kg) | 143 | 89 | 125 | 143 | 89 | 107 | 125 | 143 | 162 | |
Installation type | IM B5 or B35 | |||||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 70W 0.21A | |||||||||
Overall dimension (refer to figures) |
A | 265 | 265 | 265 | 265 | 265 | 265 | 265 | 265 | 265 |
B | 132 | 132 | 132 | 132 | 132 | 132 | 132 | 132 | 132 | |
C | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | |
D | 265 | 265 | 265 | 265 | 265 | 265 | 265 | 265 | 265 | |
E | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | |
F | 577 | 442 | 532 | 577 | 442 | 487 | 532 | 577 | 632 | |
G | 437 | 302 | 392 | 437 | 302 | 347 | 392 | 437 | 492 | |
H | 230h7 | 230h7 | 230h7 | 230h7 | 230h7 | 230h7 | 230h7 | 230h7 | 230h7 | |
I | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | |
J | 55h6 | 48h6 | 48h6 | 48h6 | 48h6 | 48h6 | 48h6 | 55h6 | 55h6 | |
K | 256 | 256 | 256 | 256 | 256 | 256 | 256 | 256 | 256 | |
L | 135 | 135 | 135 | 135 | 135 | 135 | 135 | 135 | 135 | |
N | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 230 | |
P | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Q | 360 | 225 | 315 | 360 | 225 | 270 | 315 | 360 | 415 | |
S | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | |
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Z | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
The main technical parameters of three-phase 380V/440V spindle motor and its overall dimension(List 1-6)
Model | ZJY265A-7.5BH | ZJY265A-11BH | ZJY265A-15BH | ZJY320A-18.5WL | ZJY320A-22WL | ZJY320A-30BL | ZJY320A-37BL | ZJY320A-45BL | |
Item | |||||||||
Rated power(kW) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
Adaptive driver | GS/GR3100 | GS/GR3148 | GS/GR3150 | GS/GR3198 | GS/GR3198 | GS/GR3300 | GS/GR3300 | GS/GR3300 | |
Drive power supply(V) | Three-phase AC 380/440V 50/60Hz | ||||||||
Rated current(A) | 21 | 30 | 40.7 | 51 | 58 | 69 | 87 | 100 | |
Rated | 51.7 | 51.7 | 51.7 | 26.1 | 26 | 51.2 | 51.1 | 51.1 | |
frequency(Hz) | |||||||||
Rated torque(N·m) | 48 | 70 | 95 | 235 | 280 | 191 | 235 | 286 | |
30min power(kW) | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
30min current(A) | 28.5 | 38.3 | 42.7 | 59 | 73 | 83 | 102 | 115 | |
30min torque(N·m) | 70 | 95 | 118 | 280 | 381 | 235 | 286 | 352 | |
Rated speed(r/min) | 1500 | 1500 | 1500 | 750 | 750 | 1500 | 1500 | 1500 | |
Constant power range(r/min) | 1500~8000 | 1500~8000 | 1500~8000 | 750~3500 | 750~3500 | 1500~4500 | 1500~4500 | 1500~4500 | |
Max. speed(r/min) | 10000 | 10000 | 10000 | 4500 | 4500 | 4500 | 4500 | 4500 | |
Moment of inertia(kg·m2) | 0. 0571 | 0.571 | 0.571 | 0.2997 | 0.345 | 0.24 | 0.2997 | 0.348 | |
Weight(kg) | 89 | 107 | 125 | 249 | 285 | 208 | 249 | 293 | |
Installation type | IM B5 or B3 | IM B35 | |||||||
Cooling fan power supply | Three-phase AC 380~440V 50/60Hz 70W 0.21A | Three-phase AC 380~440V 50/60Hz 60W 0.22A | |||||||
Overall dimension (refer to figures) |
A | 265 | 265 | 265 | 320 | 320 | 320 | 320 | 320 |
B | 132 | 132 | 132 | \ | \ | \ | \ | \ | |
C | 185 | 185 | 185 | 193 | 193 | 193 | 193 | 193 | |
D | 265 | 265 | 265 | 350 | 350 | 350 | 350 | 350 | |
E | 110 | 110 | 110 | 140 | 140 | 140 | 140 | 140 | |
F | 442 | 487 | 532 | 715 | 765 | 645 | 715 | 785 | |
G | 302 | 347 | 392 | 450 | 500 | 380 | 450 | 520 | |
H | 230h7 | 230h7 | 230h7 | 300h7 | 300h7 | 300h7 | 300h7 | 300h7 | |
I | 14 | 14 | 14 | 19 | 19 | 19 | 19 | 19 | |
J | 48h6 | 48h6 | 48h6 | 60h6 | 60h6 | 60h6 | 60h6 | 60h6 | |
K | 256 | 256 | 256 | \ | \ | \ | \ | \ | |
L | 135 | 135 | 135 | 165 | 165 | 165 | 165 | 165 | |
N | 230 | 230 | 230 | 279 | 279 | 279 | 279 | 279 | |
P | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | |
Q | 225 | 270 | 315 | 529 | 579 | 459 | 529 | 599 | |
S | 110 | 110 | 110 | \ | \ | \ | \ | \ | |
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Z | 15 | 15 | 15 | 19 | 19 | 19 | 19 | 19 |
The main technical parameters of three-phase 220V spindle motor and its overall dimension(List 2-1)
Model | ZJY182A-3.7BL | ZJY182A-5.5BL | ZJY182A-1.5BH | ZJY182A-2.2BH | ZJY182A-3.7BH | ZJY182A-5.5BH | ZJY182A-3.7EG | ZJY182A-5.5EG | ZJY182A-7.5EG | |
Item | ||||||||||
Rated power(kW) | 3.7 | 5.5 | 1.5 | 2.2 | 3.7 | 5.5 | 3.7 | 5.5 | 7.5 | |
Adaptive driver | GS/GR2075 | GS/GR2100 | GS/GR2050 | GS/GR2050 | GS/GR2100 | GS/GR2100 | GS/GR2100 | GS/GR2100 | GS/GR2148 | |
Drive power supply(V) | Three-phase AC 220V 50/60Hz | |||||||||
Rated current(A) | 17.9 | 23.9 | 10.7 | 12.9 | 23.5 | 30 | 20 | 28.8 | 35 | |
Rated | 53.7 | 53.5 | 53.9 | 53.6 | 53.1 | 53.5 | 103.2 | 103.3 | 103.2 | |
frequency(Hz) | ||||||||||
Rated torque(N·m) | 24 | 35 | 9.5 | 14 | 24 | 35 | 11.8 | 17.5 | 24 | |
30min power(kW) | 5.5 | 7.5 | 2.2 | 3.7 | 5.5 | 7.5 | 5.5 | 7.5 | 11 | |
30min current(A) | 25.2 | 31.1 | 17.6 | 20 | 36.4 | 40.7 | 26.7 | 35.8 | 47.3 | |
30min torque(N·m) | 35 | 48 | 14 | 24 | 35 | 48 | 17.5 | 24 | 35 | |
Rated speed(r/min) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 3000 | 3000 | 3000 | |
Constant power range(r/min) | 1500-4500 | 1500-4500 | 1500~8000 | 1500~8000 | 1500~8000 | 1500~8000 | 3000~12000 | 3000~12000 | 3000~12000 | |
Max. speed(r/min) | 4500 | 4500 | 10000 | 10000 | 10000 | 10000 | 15000 | 15000 | 15000 | |
Moment of inertia(kg·m2) | 0.0068 | 0.5712 | 0.004 | 0.0054 | 0.0083 | 0.5712 | 0.0054 | 0.0068 | 0.0083 | |
Weight(kg) | 37 | 52 | 27 | 32 | 43 | 52 | 32 | 37 | 43 | |
Installation type | IM B5 or B35 | |||||||||
Cooling fan power supply | Three-phase AC 220V 50/60Hz 37W 0.1A | |||||||||
Overall dimension (refer to figures) |
A | 182 | 182 | 182 | 182 | 182 | 182 | 182 | 182 | 182 |
B | 91 | 91 | 91 | 91 | 91 | 91 | 91 | 91 | 91 | |
C | 123 | 123 | 123 | 123 | 123 | 123 | 123 | 123 | 123 | |
D | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | |
E | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | |
F | 371 | 436 | 319 | 346 | 401 | 436 | 346 | 371 | 401 | |
G | 249 | 314 | 197 | 224 | 279 | 314 | 224 | 249 | 279 | |
H | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | 150h7 | |
I | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
J | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | 28h6 | |
K | 184 | 184 | 158 | 158 | 158 | 158 | 158 | 158 | 158 | |
L | 93 | 93 | 93 | 93 | 93 | 93 | 93 | 93 | 93 | |
N | 156 | 156 | 156 | 156 | 156 | 156 | 156 | 156 | 156 | |
P | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | |
Q | 184 | 249 | 132 | 159 | 214 | 249 | 159 | 184 | 214 | |
S | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | |
T | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
Z | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
The main technical parameters of three-phase 220V spindle motor and its overall dimension(List 2-2)
Model | ZJY208A-3.7WL | ZJY208A-2.2AM | ZJY208A-3.7AM | ZJY208A-5.5AM | ZJY208A-5.5BL | ZJY208A-7.5BL | ZJY208A-9BL | ZJY208A-3.7BM | |
Item | |||||||||
Rated power(kW) | 3.7 | 2.2 | 3.7 | 5.5 | 5.5 | 7.5 | 9 | 3.7 | |
Adaptive driver | GS/GR2075 | GS/GR2050 | GS/GR2075 | GS/GR2100 | GS/GR2100 | GS/GR2100 | GS/GR2148 | GS/GR2075 | |
Drive power supply(V) | Three-phase AC 220V 50/60Hz | ||||||||
Rated current(A) | 19.6 | 11.6 | 17.7 | 28.2 | 22.4 | 31 | 37.5 | 14.9 | |
Rated | 27.3 | 35.7 | 35.7 | 35.7 | 53.3 | 52.9 | 52.6 | 52.9 | |
frequency(Hz) | |||||||||
Rated torque(N·m) | 47 | 21 | 35 | 53 | 35 | 48 | 57.3 | 24 | |
30min power(kW) | 5.5 | 3.7 | 5.5 | 7.5 | 7.5 | 11 | 12 | 5.5 | |
30min current(A) | 27.3 | 18.4 | 24.6 | 35.5 | 28 | 41.3 | 46.2 | 22 | |
30min torque(N·m) | 70 | 35 | 53 | 72 | 48 | 70 | 76.4 | 35 | |
Rated speed(r/min) | 750 | 1000 | 1000 | 1000 | 1500 | 1500 | 1500 | 1500 | |
Constant power range(r/min) | 750-3500 | 1000-4000 | 1000~4000 | 1000~4000 | 1500~4500 | 1500~4500 | 1500~4500 | 1500~5000 | |
Max. speed(r/min) | 4500 | 7000 | 7000 | 7000 | 4500 | 4500 | 4500 | 7000 | |
Moment of inertia(kg·m2) | 0.571 | 0.0142 | 0.0196 | 0.571 | 0.0143 | 0.0196 | 0.571 | 0.0142 | |
Weight(kg) | 77 | 51 | 66 | 77 | 51.5 | 66 | 77.5 | 51 | |
Installation type | IM B5 or B35 | ||||||||
Cooling fan power supply | Three-phase AC 220V 50/60Hz 40W 0.14A | ||||||||
Overall dimension (refer to figures) |
A | 208 | 208 | 208 | 208 | 208 | 208 | 208 | 208 |
B | 104 | 104 | 104 | 104 | 104 | 104 | 104 | 104 | |
C | 160 | 160 | 160 | 160 | 160 | 160 | 160 | 160 | |
D | 215 | 215 | 215 | 215 | 215 | 215 | 215 | 215 | |
E | 80 | 60 | 80 | 80 | 80 | 80 | 110 | 60 | |
F | 524 | 414 | 469 | 524 | 414 | 469 | 524 | 414 | |
G | 395 | 285 | 340 | 395 | 285 | 340 | 395 | 285 | |
H | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | 180h7 | |
I | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | |
J | 38h6 | 28h6 | 38h6 | 38h6 | 38h6 | 38h6 | 48h6 | 28h6 | |
K | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | |
L | 106 | 106 | 106 | 106 | 106 | 106 | 106 | 106 | |
N | 180 | 180 | 180 | 180 | 180 | 180 | 180 | 180 | |
P | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Q | 320 | 210 | 265 | 320 | 210 | 265 | 320 | 210 | |
S | 80 | 80 | 80 | 80 | 80 | 80 | 110 | 60 | |
T | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Z | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
The main technical parameters of three-phase 220V spindle motor and its overall dimension(List 2-3)
The main technical parameters of three-phase 220V spindle motor and its overall dimension(List 2-4)
The main technical parameters of three-phase 220V spindle motor and its overall dimension(List 2-5)
The main technical parameters of dual speed motor and its overall dimension(List 3)
Company Profile
GSK CNC Equipment Co., Ltd.
GSK CNC Equipment Co., Ltd. (hereinafter referred as GSK) is specially devoted to conducting research and practice of basic equipment industrial development, providing “trinity” packaged solutions of machine tool CNC system, servo drive and servo motor, taking initiative in the expansion of industrial robot and all-electric injection molding machine field, developing the new marketing mode of machine tool exhibition hall, providing the customers with all-round professional machine tool remanufacturing solutions and services, promoting the integration of production and education, setting up the vocational education and training institute, as well as conducting highly skilled CNC personnel training. It has developed into a high-tech enterprise integrating science, education, industry and trade, thus being known as “China Southern CNC Industrial Base”.
Adhering to the corporate philosophy of “making itself a century-old enterprise and building gold quality” and the service spirit of “keeping improvement and making users satisfied”, GSK enhances the user product value & benefits through continuous technological progress and innovation, and makes unremitting efforts to promote the localization process of basic equipment industry, improve the technological level of the industry, and promote the development of China’s national equipment manufacturing industry.
Main products:
GSK CNC System Idustrial robot
Full electric injection molding machine CNC machine
International exhibition
Exhibition hall
218MC USB Reading Problem Solution
218MC USB Reading Problem Solution
FAQ
Payments
1) We can accept EXW, FOB
2) Payment must be made before shipment.
3) Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer’s responsibility.
Shipping
1) We only ship to your confirmed address. Please make sure your shipping address is correct before purchase.
2) Most orders will be shipped out within 3-7 working days CHINAMFG payment confirmation.
3) Shipping normally takes 7-25 working days. Most of the items will delivery in 2 weeks, while there will be a delay for something we cannot control (such as the bad weather). If it happens, just contact us, we will help you check and resolve any problem.
3) Please check the package CHINAMFG receipt, if there are some damages, please contact us immediately.
Feedback & Refund
1) Feedback is important to us, if you have any problem with our products, please contact us, our technician will give you useful advises.
2) When you have the parcel and not satisfied with the goods or it is other problem, please tell us immediately, and provide us a photo showing the detail.
3) Any reason requiring for all refund. Items must be in original condition and no physical damage. Buyer responsible for all shipping cost.
If you need more information, please contact with us. We will attach great importance to your any problems.
Hope we could establish a long-term effective cooperation.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Application: | Industrial |
---|---|
Speed: | Variable Speed |
Number of Stator: | Three-Phase |
Function: | Driving, Control |
Casing Protection: | Protection Type |
Starting Mode: | Auto-induction Voltage-reduced Starting |
Customization: |
Available
|
|
---|
Can AC motors be used in both residential and commercial settings?
Yes, AC motors can be used in both residential and commercial settings. The versatility and wide range of applications of AC motors make them suitable for various environments and purposes.
In residential settings, AC motors are commonly found in household appliances such as refrigerators, air conditioners, washing machines, fans, and pumps. These motors are designed to meet the specific requirements of residential applications, providing reliable and efficient operation for everyday tasks. For example, air conditioners utilize AC motors to drive the compressor and fan, while washing machines use AC motors for agitating and spinning the drum.
In commercial settings, AC motors are extensively used in a wide range of applications across different industries. They power machinery, equipment, and systems that are crucial for commercial operations. Some common examples include:
- Industrial machinery and manufacturing equipment: AC motors drive conveyor belts, pumps, compressors, mixers, fans, blowers, and other machinery used in manufacturing, production, and processing facilities.
- HVAC systems: AC motors are used in commercial heating, ventilation, and air conditioning (HVAC) systems to drive fans, blowers, and pumps for air circulation, cooling, and heating.
- Commercial refrigeration: AC motors are utilized in commercial refrigeration systems for powering compressors, condenser fans, and evaporator fans in supermarkets, restaurants, and cold storage facilities.
- Office equipment: AC motors are present in various office equipment such as printers, photocopiers, scanners, and ventilation systems, ensuring their proper functioning.
- Transportation: AC motors are used in electric vehicles, trams, trains, and other forms of electric transportation systems, providing the necessary propulsion.
- Water and wastewater treatment: AC motors power pumps, mixers, and blowers in water treatment plants, wastewater treatment plants, and pumping stations.
The adaptability, efficiency, and controllability of AC motors make them suitable for a wide range of residential and commercial applications. Whether it’s powering household appliances or driving industrial machinery, AC motors play a vital role in meeting the diverse needs of both residential and commercial settings.
Are there energy-saving technologies or features available in modern AC motors?
Yes, modern AC motors often incorporate various energy-saving technologies and features designed to improve their efficiency and reduce power consumption. These advancements aim to minimize energy losses and optimize motor performance. Here are some energy-saving technologies and features commonly found in modern AC motors:
- High-Efficiency Designs: Modern AC motors are often designed with higher efficiency standards compared to older models. These motors are built using advanced materials and optimized designs to reduce energy losses, such as resistive losses in motor windings and mechanical losses due to friction and drag. High-efficiency motors can achieve energy savings by converting a higher percentage of electrical input power into useful mechanical work.
- Premium Efficiency Standards: International standards and regulations, such as the NEMA Premium® and IE (International Efficiency) classifications, define minimum energy efficiency requirements for AC motors. Premium efficiency motors meet or exceed these standards, offering improved efficiency compared to standard motors. These motors often incorporate design enhancements, such as improved core materials, reduced winding resistance, and optimized ventilation systems, to achieve higher efficiency levels.
- Variable Frequency Drives (VFDs): VFDs, also known as adjustable speed drives or inverters, are control devices that allow AC motors to operate at variable speeds by adjusting the frequency and voltage of the electrical power supplied to the motor. By matching the motor speed to the load requirements, VFDs can significantly reduce energy consumption. VFDs are particularly effective in applications where the motor operates at a partial load for extended periods, such as HVAC systems, pumps, and fans.
- Efficient Motor Control Algorithms: Modern motor control algorithms, implemented in motor drives or control systems, optimize motor operation for improved energy efficiency. These algorithms dynamically adjust motor parameters, such as voltage, frequency, and current, based on load conditions, thereby minimizing energy wastage. Advanced control techniques, such as sensorless vector control or field-oriented control, enhance motor performance and efficiency by precisely regulating the motor’s magnetic field.
- Improved Cooling and Ventilation: Effective cooling and ventilation are crucial for maintaining motor efficiency. Modern AC motors often feature enhanced cooling systems, including improved fan designs, better airflow management, and optimized ventilation paths. Efficient cooling helps prevent motor overheating and reduces losses due to heat dissipation. Some motors also incorporate thermal monitoring and protection mechanisms to avoid excessive temperatures and ensure optimal operating conditions.
- Bearings and Friction Reduction: Friction losses in bearings and mechanical components can consume significant amounts of energy in AC motors. Modern motors employ advanced bearing technologies, such as sealed or lubrication-free bearings, to reduce friction and minimize energy losses. Additionally, optimized rotor and stator designs, along with improved manufacturing techniques, help reduce mechanical losses and enhance motor efficiency.
- Power Factor Correction: Power factor is a measure of how effectively electrical power is being utilized. AC motors with poor power factor can contribute to increased reactive power consumption and lower overall power system efficiency. Power factor correction techniques, such as capacitor banks or power factor correction controllers, are often employed to improve power factor and minimize reactive power losses, resulting in more efficient motor operation.
By incorporating these energy-saving technologies and features, modern AC motors can achieve significant improvements in energy efficiency, leading to reduced power consumption and lower operating costs. When considering the use of AC motors, it is advisable to select models that meet or exceed recognized efficiency standards and consult manufacturers or experts to ensure the motor’s compatibility with specific applications and energy-saving requirements.
What is an AC motor, and how does it differ from a DC motor?
An AC motor, also known as an alternating current motor, is a type of electric motor that operates on alternating current. It converts electrical energy into mechanical energy through the interaction of magnetic fields. AC motors are widely used in various applications, ranging from household appliances to industrial machinery. Here’s a detailed explanation of what an AC motor is and how it differs from a DC motor:
AC Motor:
An AC motor consists of two main components: the stator and the rotor. The stator is the stationary part of the motor and contains the stator windings. These windings are typically made of copper wire and are arranged in specific configurations to create a rotating magnetic field when energized by an alternating current. The rotor, on the other hand, is the rotating part of the motor and is typically made of laminated steel cores with conducting bars or coils. The rotor windings are connected to a shaft, and their interaction with the rotating magnetic field produced by the stator causes the rotor to rotate.
The operation of an AC motor is based on the principles of electromagnetic induction. When the stator windings are energized with an AC power supply, the changing magnetic field induces a voltage in the rotor windings, which in turn creates a magnetic field. The interaction between the rotating magnetic field of the stator and the magnetic field of the rotor produces a torque, causing the rotor to rotate. The speed of rotation depends on the frequency of the AC power supply and the number of poles in the motor.
DC Motor:
A DC motor, also known as a direct current motor, operates on direct current. Unlike an AC motor, which relies on the interaction of magnetic fields to generate torque, a DC motor uses the principle of commutation to produce rotational motion. A DC motor consists of a stator and a rotor, similar to an AC motor. The stator contains the stator windings, while the rotor consists of a rotating armature with coils or permanent magnets.
In a DC motor, when a direct current is applied to the stator windings, a magnetic field is created. The rotor, either through the use of brushes and a commutator or electronic commutation, aligns itself with the magnetic field and begins to rotate. The direction of the current in the rotor windings is continuously reversed to ensure continuous rotation. The speed of a DC motor can be controlled by adjusting the voltage applied to the motor or by using electronic speed control methods.
Differences:
The main differences between AC motors and DC motors are as follows:
- Power Source: AC motors operate on alternating current, which is the standard power supply in most residential and commercial buildings. DC motors, on the other hand, require direct current and typically require a power supply that converts AC to DC.
- Construction: AC motors and DC motors have similar construction with stators and rotors, but the design and arrangement of the windings differ. AC motors generally have three-phase windings, while DC motors can have either armature windings or permanent magnets.
- Speed Control: AC motors typically operate at fixed speeds determined by the frequency of the power supply and the number of poles. DC motors, on the other hand, offer more flexibility in speed control and can be easily adjusted over a wide range of speeds.
- Efficiency: AC motors are generally more efficient than DC motors. AC motors can achieve higher power densities and are often more suitable for high-power applications. DC motors, however, offer better speed control and are commonly used in applications that require precise speed regulation.
- Applications: AC motors are widely used in applications such as industrial machinery, HVAC systems, pumps, and compressors. DC motors find applications in robotics, electric vehicles, computer disk drives, and small appliances.
In conclusion, AC motors and DC motors differ in their power source, construction, speed control, efficiency, and applications. AC motors rely on the interaction of magnetic fields and operate on alternating current, while DC motors use commutation and operate on direct current. Each type of motor has its advantages and is suited for different applications based on factors such as power requirements, speed control needs, and efficiency considerations.
editor by CX 2024-04-30