Large Pace Everlasting Magnetic Synchronous Reluctance Motor
Solution Attribute
one.Ideal for the 12000rpm high speed
2.Reserve a huge margin of protection
three.High electricity & higher torque
4.Substantial effectiveness
5.Small measurement
six.Minimal sounds lower vibration
7.The autonomous patented cooling structure
Specifications
Design variety: SRPM112H4W10
Voltage: 230V AC
Rated Energy: 10KW
Rated Torque:8N.m
Rated Speed: 12000rpm
Highest Speed:13500rpm
Isolation: H
Cooling Strategy: h2o cooling
Ingress Safety:IP54(IP67 option)
Pole:4
Software
one.Hydrogen Oxygen air compressors
2.Hydrogen circulating technique
Other motors you will be intrigued in
Motor sort | Voltage (V AC) |
Rated electricity (kW) |
Rated torque (N.m) | Rated velocity (rpm) |
Performance (%) |
Responsibility type | Insulation | Ingress protection | Pole Variety | Bodyweight (kg) |
Cooling Method | position sign |
SRPM160H4XO15 | 380 | fifteen | 5.96 | 24000 | ninety six.5 | S1 | H/F | IP67 | four | twelve | Oil | Resolver |
SRPM160H4XO75 | 380 | 75 | 35.eight | 20000 | 96.5 | S1 | H/F | IP67 | four | forty four | Oil | Resolver |
SRPM160H4XO90 | 380 | 90 | forty three | 20000 | 96.five | S1 | H/F | IP67 | four | forty eight | Oil | Resolver |
SRPM205H4XO110 | 380 | one hundred ten | 52.5 | 20000 | 96.five | S1 | H/F | IP67 | four | seventy six | Oil | Resolver |
SRPM205H4XO160 | 380 | 160 | 76.four | 20000 | 96.5 | S1 | H/F | IP67 | four | 86 | Oil | Resolver |
SRPM205H4XO200 | 380 | two hundred | 95.five | 20000 | 96.5 | S1 | H/F | IP67 | four | 95 | Oil | Resolver |
FAQ
1. Can performanent magnet synchronous motor be employed as generator?
No. Long term magnet synchronous motor is absolutely various from generator. It is only ac motor that outputs speed and torque to push electric devices, but not electrical power source.
two. Why can not immediately use 3 phase ac offer voltage to commence long term magnet synchronous motor?
Becuase rotor is with big innertia, and magetic data files spins so rapidly that static rotor has no way to spin with magetic filed.
3. Any specific complex request on this motor’s VFD driver? And Do you have this kind of driver?
Permanent magnet synchronous motor’s driver should be vector manage VFD with special inner application, this sort of as Siemens 6SE70 collection, Yakawa CR5 collection, ABB ACS800 collection, Mitsubishi A740 sequence, B&R P84 and P74 collection, etc.. Sure, our MH300 series VFD matches with this motor.
4. Is there any protecting measures to defend long lasting magnet rotor from failure?
Sure, each long term magnet rotor passes corrossion resistance, consistency, higher temperature demagnetization check, linear demagnetization test, and so on. Its demagnetization index is within 2%. But if doing work setting is critical oxiditive corrosion, kindly advise for increased defense level.
5. Where is this everlasting magnet synchronous motor normally utilised to?
This long lasting magnet synchronous motor is usually utilized to variable frequency pace scenario.